Quantum Disinfection

No power. No pathogens

Quantum Disinfection™

Is a revolutionary technology that uses quantum mechanics principles of electron movement to create catalytic active surfaces. This is the first time such a technology has been used to disinfect water. 

Quantum Disinfection™ (QD) is a new generation of nano-composite materials with activated surfaces that kills pathogens like bacteria (E. coli, Staphylococcus, Legionella, etc.), viruses (MS2) and protozoa (Cryptosporidium) from water, with no power, no chemicals and no maintenance. Quantum Disinfection™ is a revolutionary technology that uses the quantum mechanics principles of electron movements in micro-crystals creating powerful catalysts applied for drinking water purification. 

Quantum Disinfection™ is a catalyst: disinfects the water with its activated surfaces, no power, no chemicals, no maintenance. 

 

Quantum Disinfection™ is a ceramic:  

alumina based, environmentally friendly, odorless and insoluble.  

 

Quantum Disinfection™ is a new phenomenon:  

attracts electrons from microorganisms causing their entire structure to collapse. 

 

Quantum Disinfection™ is a solid media: 

easy to apply, easy to handle, always placed in packed beds. 

 

Quantum Disinfection™ kills the microorganisms instantly: 

there is no contact time required, there are no traces of microorganisms. 

 

Water simply has to pass over the Quantum Disinfection™ media and the 
microorganisms are instantly destroyed through the catalytic electron exchange. 

Give Any Device Disinfection Capability.

Point-of-Entry

 QD is used in systems for well water and city high

 

water sources for homes, offices, and process pitcher

 

applications: up to 12 GPM.

Point-of-Use

A small quantity of QD can disinfect all POU

systems such as faucets, under the sink units,

   ice and beverage machines, coolers, misters,

 showers, dental chairs, etc.

Gravity-Based

With no power requirements and allowing
gravitational flows, QD can disinfect all
evices, bracket units, suspended tanks, etc.

Quantum Disinfection™ Frequently Asked Questions

How does Quantum Disinfection™ work?

QD is a catalyst with activated surfaces. The microorganisms (bacteria, viruses, protozoa, micro-algae, yeast, etc.) that get into a direct contact with these surfaces, instantly lose their electrons to the positive active sites causing their entire structure to collapse. 

Is QD a filter?

No. It is a disinfection media. Besides, just like UV, QD needs primary filtration (at least 5 micron) to work properly, otherwise the activated sites can be clogged. 

Does QD media leaches?

No. Quantum Disinfection™ does not leach anything in the water, no ions, no chemicals. All of the bactericidal action happens because of a catalytic surface action. 

Is QD certified?

Yes. QD media is:  

  • A NSF Certified Component to NSF/ANSI 42 for material requirements only (Certificate #: C0292640-01);  
  • Tested by IAPMO to NSF/ANSI 61 (Certificate #: 23033); 
  • Certified MOH – (Certificate #: 2015KF2513). 

How QD is applied?

QD can only be applied in packed bed in devices, systems or units with a inlet and an outlet that can ensure the contact of the microorganisms with the activated ceramics. No by-pass is allowed. 

Has QD been tested by 3rd party labs?

Yes. Quantum Disinfection™ technology has been rigorously tested and posted excellent results by: 

  • Environmental Protection Agency, US EPA 
  • Eurofins US; Eurofins France  
  • NC State University 
  • Proteus, France  
  • Avazyme, US  
  • Ackuritlabs, US 
  • Microbac, US 

All of these reports are available upon request. 

Is Quantum Disinfection™ a purifier like Reverse Osmosis?

No. Quantum Disinfection™ is more like UV. It is not a filter and its purpose is not to filter the water, but rather to disinfect the water. 

How long does QD media last?

Claire works closely with our OEM partners to design cartridges and devices that meet end-of-life criteria. For Claire’s own prototypes, such as the CLAIRIFY 12 unit, the warrantied life is 200,000 gallons, or just over 1 year of normal household use. 

Far from the classical disinfection methods (chlorine, alcohol, bromide, ozone or UV), the QD ceramic catalysts have a discharged surface (a positive quantum field) that attracts electrons. Water simply has to pass over this media and the microorganisms (negatively charged) are instantly killed

Quantum Ceramics are made in Canada

Quantum Systems are made in the USA

Item Part Number: CT12

 

Applications: Point-of-Entry Point-of-Use

 

Power Requirements:

 

None Quantity of QD ceramics: 660 grams

 

Maximum Flow *: 12 GPM

 

System Dimensions: 11 x 3 inch

 

Maximum Pressure **: 125 psi

 

Capacity: 200,000 gallons

 

Water Temperature: 41 – 100 ºF

 

Inlet/Outlet Connections ***: 1 inch – FTG / NPT male

Item Part Number: CTAG

 

Applications: Point-of-Use  

 

Power Requirements: None  

 

Quantity of QD ceramics: 380 grams  

 

Maximum Flow: * 7 GPM  

 

System Dimensions: 12 x 2.5 inch  

 

Maximum Pressure **:  125 psi  

 

Capacity: 100,000 gallons  

 

Water Temperature: 41 – 100 ºF  

 

Inlet/Outlet Connections ***: 3/4-inch M X F – Garden Hose

 

Item Part Number: CTO2 

 

Applications: Point-of-Use  

 

Power Requirements: None  

 

Quantity of QD ceramics120 grams  

 

Maximum Flow: * 2 GPM  

 

System Dimensions6 x 2 inch  

 

Maximum Pressure **:  125 psi  

 

Capacity: 37,000 gallons

  

Water Temperature: 41 – 100 ºF  

 

Inlet/Outlet Connections ***: 3/8-inch – QC (push in) 

Item Part Number: CTO1 

 

Applications: Point-of-Use  

 

Power Requirements: None  

 

Quantity of QD ceramics70 grams 

 

Maximum Flow: * 1 GPM  

 

System Dimensions12 X 3 inch  

 

Maximum Pressure **:  20-125 psi  

 

Capacity: 15,000 gallons 

 

Water Temperature: 41 – 100 ºF  

 

Inlet/Outlet Connections ***: 3/8-inch – QC (push in) 

 

* The system contains: – 20 grams of QD ceramics – 150 grams of Granular Activated Carbon 

Item Part Number: CTO6 

 

Applications: Point-of-Use  

 

Power Requirements: None  

 

Quantity of QD ceramics20 grams  

 

Maximum Flow:  0.5 GPM  

 

System Dimensions10 X 2 inch  

 

Maximum Pressure **:  125 psi  

 

Capacity: 3,000 gallons  

 

Water Temperature: 41 – 100 ºF  

 

Inlet/Outlet Connections ***: 1/4-inch – QC (push in) 

 

* The system contains: – 20 grams of QD ceramics – 150 grams of Granular Activated Carbon

Item Part Number: CTO6 

 

Applications: Point-of-Use  

 

Power Requirements: None  

 

Quantity of QD ceramics20 grams  

 

Maximum Flow:  0.5 GPM  

 

System Dimensions6 X 2 inch  

 

Maximum Pressure **:  125 psi  

 

Capacity: 3,000 gallons 

 

Water Temperature: 41 – 100 ºF  

 

Inlet/Outlet Connections ***: 1/4-inch – QC (push in) 

 

* The system contains: – 20 grams of QD ceramics – 80 grams of Granular Activated Carbon 

Media price call for quote. You can fill filter housings with this media for larger operations and larger flows.

 

Microorganism (MO) 

MO type 

Best germicide efficiency 

(log reduction/100ml) 

Certified Laboratory 

Pseudomonas aeruginosa 

bacteria 

log 7 

PIL, Proteus 

Escherichia coli 

log 7 

EPA, AvazymeEurofineMicrobac, Proteus, Ackuritlabs, GDCM, BFML 

Staphylococcus aureus 

log 7 

PIL, Proteus, BFML 

Eterococcus hirae 

log 10 

Ackuritlabs, PIL, Proteus 

Legionella adelaidensis 

log 6 

Proteus 

Citrobacter sp 

log 5 

PIL 

MS2 

virus 

log 6 

Avazyme, QFT Laboratory 

Candida albicans 

yeast 

log 5 

Proteus 

Anabaena constricta 

algae 

log 5 

Proteus 

Cryptosporidium 

protozoa 

log 5 

Eurofines 