Quantum Water Disinfection Treatment System

QUANTUM DISINFECTION™

No Power. No Pathogens

Is a revolutionary technology that uses quantum mechanics principles of electron movement to create catalytic active surfaces. This is the first time such a technology has been used to disinfect water. Quantum Disinfection™ (QD) is a new generation of nano-composite materials with activated surfaces that kills pathogens like bacteria (E. coli, Staphylococcus, Legionella, etc.), viruses (MS2), and protozoa (Cryptosporidium) from water with no power, no chemicals, and no maintenance. Quantum Disinfection™ is a revolutionary technology that uses the quantum mechanics principles of electron movements in micro-crystals to create powerful catalysts applied for drinking water purification.

Quantum Disinfection™ is a catalyst that disinfects the water with its activated surfaces with no power, no chemicals, and no maintenance.

Quantum Disinfection™ is a ceramic:

alumina based, environmentally friendly, odorless and insoluble.

Quantum Disinfection™ is a new phenomenon:

attracts electrons from microorganisms causing their entire structure to collapse.

Quantum Disinfection™ is a solid media:

easy to apply, easy to handle, always placed in packed beds.

Quantum Disinfection™ kills the microorganisms instantly:

There is no contact time required, and there are no traces of microorganisms.

Water simply has to pass over the Quantum Disinfection™ medium, and the microorganisms are instantly destroyed through the catalytic electron exchange.

Give Any Device Disinfection Capability

Point-of-entry

QD is used in systems for well water and city high water sources for homes, offices, and process pitcher applications: up to 12 GPM.

Point-of-use

A small quantity of QD can disinfect all POU systems such as faucets, under the sink units, ice and beverage machines, coolers, misters, showers, dental chairs, etc.

Gravity-based

With no power requirements and allowing gravitational flows, QD can disinfect all evices, bracket units, suspended tanks, etc.

Quantum Disinfection™ - Frequently Asked Questions

QD is a catalyst with activated surfaces. The microorganisms (bacteria, viruses, protozoa, micro-algae, yeast, etc.) that get into direct contact with these surfaces instantly lose their electrons to the positive active sites, causing their entire structure to collapse.

No. It is a disinfection medium. Besides, just like UV, QD needs primary filtration (at least 5 microns) to work properly; otherwise, the activated sites can be clogged.

No. Quantum Disinfection™ does not leach anything in the water—no ions, no chemicals. All of the bactericidal action happens because of catalytic surface action.

Yes. QD media is:

  • A NSF component to NSF/ANSI 42 for material requirements only (Certificate #: C0292640-01);
  • Tested by IAPMO to NSF/ANSI 61 (Certificate #: 23033);
  • Certified MOH (Certificate #: 2015KF2513).

QD can only be applied in packed beds in devices, systems, or units with an inlet and an outlet that can ensure the contact of the microorganisms with the activated ceramics. No by-pass is allowed.

Yes. Quantum Disinfection™ technology has been rigorously tested and has posted excellent results by:

  • Environmental Protection Agency, US EPA
  • Eurofins US; Eurofins France
  • NC State University
  • Proteus, France
  • Avazyme, US
  • Ackuritlabs, US
  • Microbac, US

All of these reports are available upon request.

No. Quantum Disinfection™ is more like UV. It is not a filter, and its purpose is not to filter the water but rather to disinfect the water.

Claire works closely with our OEM partners to design cartridges and devices that meet end-of-life criteria. For Claire’s own prototypes, such as the CLAIRIFY 12 unit, the warranted life is 200,000 gallons, or just over 1 year of normal household use.

Far from the classical disinfection methods (chlorine, alcohol, bromide, ozone, or UV), the QD ceramic catalysts have a discharged surface (a positive quantum field) that attracts electrons. Water simply has to pass over this medium, and the microorganisms (negatively charged) are instantly killed

Quantum Ceramics Are Made in Canada

Quantum Systems Are Made in the USA

  • Item Part Number: CT12
  • Applications: Point-of-Entry Point-of-Use
  • Power Requirements:
  • None Quantity of QD ceramics: 660 grams
  • Maximum Flow *: 12 GPM
  • System Dimensions: 11 x 3 inch
  • Maximum Pressure **: 125 psi
  • Capacity: 200,000 gallons
  • Water Temperature: 41 – 100 ºF
  • Inlet/Outlet Connections ***: 1 inch – FTG / NPT male
  • Item Part Number: CT12
  • Applications: Point-of-Entry Point-of-Use
  • Power Requirements:
  • None Quantity of QD ceramics: 660 grams
  • Maximum Flow *: 12 GPM
  • System Dimensions: 11 x 3 inch
  • Maximum Pressure **: 125 psi
  • Capacity: 200,000 gallons
  • Water Temperature: 41 – 100 ºF
  • Inlet/Outlet Connections ***: 1 inch – FTG / NPT male
  • Item Part Number: CTO2
  • Applications: Point-of-Use
  • Power Requirements: None
  • Quantity of QD ceramics: 120 grams
  • Maximum Flow: * 2 GPM
  • System Dimensions: 6 x 2 inch
  • Maximum Pressure **: 125 psi
  • Capacity: 37,000 gallons
  • Water Temperature: 41 – 100 ºF
  • Inlet/Outlet Connections ***: 3/8-inch – QC (push in)
  • Item Part Number: CTO1
  • Applications: Point-of-Use
  • Power Requirements: None
  • Quantity of QD ceramics: 70 grams
  • Maximum Flow: * 1 GPM
  • System Dimensions: 12 X 3 inch
  • Maximum Pressure **: 20-125 psi
  • Capacity: 15,000 gallons
  • Water Temperature: 41 – 100 ºF
  • Inlet/Outlet Connections ***: 3/8-inch – QC (push in)

* The system contains: – 20 grams of QD ceramics – 150 grams of Granular Activated Carbon

  • Item Part Number: CTO6
  • Applications: Point-of-Use
  • Power Requirements: None
  • Quantity of QD ceramics: 20 grams
  • Maximum Flow: 0.5 GPM
  • System Dimensions: 10 X 2 inch
  • Maximum Pressure **: 125 psi
  • Capacity: 3,000 gallons
  • Water Temperature: 41 – 100 ºF
  • Inlet/Outlet Connections ***: 1/4-inch – QC (push in)

* The system contains: – 20 grams of QD ceramics – 150 grams of Granular Activated Carbon

  • Item Part Number: CTO6
  • Applications: Point-of-Use
  • Power Requirements: None
  • Quantity of QD ceramics: 20 grams
  • Maximum Flow: 0.5 GPM
  • System Dimensions: 6 X 2 inch
  • Maximum Pressure **: 125 psi
  • Capacity: 3,000 gallons
  • Water Temperature: 41 – 100 ºF
  • Inlet/Outlet Connections ***: 1/4-inch – QC (push in)

Media Price Call for Quote. You Can Fill Filter Housings With This Media for Larger Operations and Larger Flows.

Microorganism (MO) MO type Best germicide efficiency
(log reduction/100ml)
Certified Laboratory
Pseudomonas aeruginosa log 7 PIL, Proteus
Escherichia coli log 7 EPA, Avazyme, Eurofine, Microbac, Proteus,
Ackuritlabs, GDCM, BFML
Staphylococcus aureus bacteria log 7 PIL, Proteus, BFML
Eterococcus hirae log 10 Ackuritlabs, PIL, Proteus
Legionella adelaidensis log 6 Proteus
Citrobacter sp log 5 PIL
MS2 virus log 6 Avazyme, QFT Laboratory
Candida albicans yeast log 5 Proteus
Anabaena constricta algae log 5 Proteus
Cryptosporidium protozoa log 5 Eurofines
Many options exist for
larger quantity water systems

Best Water Solutions Provider Awards

Puroxi Pure Water Global Inc was shortlisted for the awards category, Water Solutions Provider of the Year! As highlighted, it was some good news. I can confirm you that you have been chosen as the 2023/24 winners. Congratulations Zak! The generic winner’s logo has been attached which you can utilize to promote the recognition and the official press release will be conducted in March (defined date to come