Pump Selection for Nano-Bubble Systems

Select the pump from the required nozzle flow and pressure at the real operating point—not from the connection size or the pump’s maximum-flow label.

Interactive preliminary calculator

Build the Required Pump Duty Point

Enter the complete system information to estimate flow, total dynamic head and hydraulic power. This is a design starting point—not a pump-model recommendation.

How to Use the Puroxi Pump Selection Calculator

Enter the System Information

The entered nozzle pressure is below Puroxi's normal minimum starting pressure of approximately 30 psi. Please confirm the intended application.
A design allowance above 20% may unnecessarily oversize the pump. Please confirm the value entered.
Please enter a valid pump efficiency before using the estimated input-power result.
Nozzle pressure head m+Static head m+Pipe & fitting losses m+Allowance m=Total dynamic head m

The required operating point

Flow and Pressure Must Arrive at the Nozzle Together

A typical starting reference is approximately 30 psi minimum operating pressure, with many applications reviewed in the 40–60 psi range and 40–50 psi often preferred. The selected nozzle’s approved data and the project design always control. The pump curve must show that the pump can deliver the required flow after static lift, pipe friction, valves, fittings, filters, manifolds and nozzle pressure are all included.
HEAD / PRESSUREREQUIRED OPERATING POINTFLOW →

Total dynamic head

Every Restriction Belongs in the Calculation

Static lift+Pipe friction+Valves & fittings+Manifolds+Nozzle pressure= TDH

Pump curve

Use the manufacturer’s curve at the required operating point and leave a responsible design margin.

VFD control

A variable-frequency drive can trim and control a suitable pump; it cannot correct a fundamentally undersized pump or piping system.

Measure after installation

Confirm actual flow, nozzle pressure, gas delivery, motor load and the treatment response during commissioning.