Oxygen Sources
PSA oxygen generators and oxygen supply assemblies.
How Puroxi selects this equipment
Oxygen purity, delivery flow (SLPM), pressure, drying, electrical supply and generator compatibility.
Explore the equipment that can make up an engineered ozone treatment system. Compare generator capacities, understand the purpose of each accessory, and learn what information is needed to select a complete solution.
Reference catalogue only — no online sales, pricing or checkout.
The Puroxi reference range includes compact, wall/bench-mounted, rack-mounted and higher-capacity ozone generator configurations. Ozone production (g/h) is only one design factor: concentration, gas flow, operating pressure, oxygen requirements, water demand and transfer efficiency all matter.

Small-format oxygen-fed ozone generator for controlled applications.
Compare models and specifications ↓
Multiple output and concentration options for commercial and industrial systems.
Compare models and specifications ↓
Rack-mounted arrangements for integrated equipment panels.
Compare models and specifications ↓
Higher-output units for engineered treatment applications.
Compare models and specifications ↓| Product / Configuration | Rated ozone output (g/h) | Nominal pressure (psig) | Ozone concentration (% by weight) | Supply (V) | Notes |
|---|---|---|---|---|---|
| Puroxi Nano 15 | 15 | 20 | 5–10 | 120 / 230 | Compact bench or wall installation |
| Puroxi Atlas 30 | 30 | 20 | 9–12 | 120 / 230 | Standard 30 g/h |
| Puroxi Atlas 30C | 30 | 20 | 9–16 | 120 / 230 | Higher concentration variant |
| Puroxi Atlas UHC | 20 | 20 | 9–22 | 120 / 230 | Ultra-high-concentration variant |
| Puroxi Atlas 60 | 60 | 25–40 | 6–12 | 120 / 230 | Standard 60 g/h |
| Puroxi Atlas 60 LP | 20* | 20 | 6–12 | 120 / 230 | Low-pressure configuration; verify output |
| Puroxi Atlas 80 | 80 | 25–40 | 5–12 | 120 / 230 | Standard 80 g/h |
| Puroxi Atlas 100 | 100 | 30–50 | 5–12 | 120 / 230 | Standard 100 g/h |
| Puroxi Titan 30 / 30C / UHC | 30 / 30 / 20 | 20 | 9–22 depending on model | 120 / 230 | Rack-mounted variants |
| Puroxi Titan 60 / 60 LP | 60 / 20* | 25–40 / 20 | 6–12 | 120 / 230 | Standard and low-pressure configurations |
| Puroxi Titan 80 | 80 | 25–40 | 5–12 | 120 / 230 | Rack-mounted 80 g/h |
| Puroxi Titan 100 | 100 | 30–50 | 5–12 | 120 / 230 | Rack-mounted 100 g/h |
| Puroxi Magnum 120 LP | 120 | 20 | 6–12 | 230 | Low-pressure high-output model; electrical configuration requires confirmation |
| Puroxi Magnum 160 | 160 | 30–50 | 6–12 | 230 | Higher-capacity engineered systems |
| Puroxi Magnum 200 | 200 | 30–50 | 6–12 | 230 | Higher-capacity engineered systems |
Reference performance charts for engineering review. Confirm model-specific ratings and operating conditions before quoting or publishing.




Technical values are preliminary reference figures transcribed and paraphrased from the manufacturer’s published operator manual (2025 edition), not final Puroxi-issued product datasheets. The low-pressure 60 series has inconsistent output listings across public source materials; confirm the actual output and all electrical requirements before publishing or quoting. “Puroxi” names here are proposed private-label presentation names pending approved product labels and manuals.
Equipment photographs shown are illustrative; final component selection and ozone compatibility are confirmed during engineering review.
Browse the accessory families used to assemble an ozone treatment system. Expand any category to see what it does and the information required for selection.

PSA oxygen generators and oxygen supply assemblies.
Oxygen purity, delivery flow (SLPM), pressure, drying, electrical supply and generator compatibility.

Premium ozone injection and gas-to-water transfer option.
Nozzle material compatibility, pump duty point, water flow, pressure, gas feed and contact configuration. Product-specific ozone compatibility must be verified.

Differential-pressure ozone gas injection.
Water flow, inlet/outlet pressures, suction capability, gas flow and ozone-compatible wetted materials.
Downstream mixing after suitable gas injection.
Pipe size, hydraulic loading, pressure loss, material compatibility and required mass transfer.

Controlled reaction and contact arrangements.
Effective contact volume, hydraulic short-circuiting, retention time, pressure, venting and water-quality objectives.
Removal of undissolved ozone-bearing gas.
Gas flow, separation efficiency, pressure, ventilation and routing to ozone destruction.

Catalytic or thermal destruction of residual off-gas ozone.
Maximum ozone concentration, gas flow, humidity, operating conditions, discharge limits and service access.

Dissolved ozone, ambient ozone, ORP and other instruments.
Measurement range, calibration, sample conditions, alarms and shutdown interlocks.

Gas and water flow regulation and measurement.
Operating flow range, pressure rating, ozone compatibility and control strategy.

Protect generators and oxygen equipment from water ingress.
Ozone-rated check valves, water traps, pressure protection and automatic shutdown.

Gas lines, valves, tubing and fittings selected for ozone service.
Material, seal, pressure, temperature and concentration compatibility.

Air supply where appropriate for the selected equipment.
Feed-gas specification, filtration, moisture management and generator requirements.

Move water through injection and contact equipment.
Pump curves, operating pressure, water chemistry, serviceability and required turnover.
Water source, chemistry, BOD and COD where relevant, bromide for potable applications, temperature, existing treatment and the desired outcome.
Flow rate, system volume, turnover per day, operating hours, recirculation, pressure and the available installation space.
Match oxygen supply, generator, ozone-compatible injection, mixing, contact vessel, off-gas treatment, monitoring and protective interlocks.
Confirm equipment suitability, local regulations, site safety, residual limits and any required pilot testing before a final quotation.
Use our preliminary calculator to organize your information. It is not an automatic generator sizing or equipment purchasing tool.
Open Ozone Calculator → Contact a Water Specialist →Canadian applications: ozone-generator use and claims must be reviewed against applicable Canadian regulatory restrictions, including limitations on pesticidal/disinfection claims. Potable water, bottled water and aquaculture systems require application-specific compliance and safety assessment.