Ozone Generator

Features:

  • Inner air compressor and condenser water filter
  • Ozone adjustable from 0-100%
  • Ozone adjustable from 0-100%
  • Backwater prevention solenoid valve
  • Stainless steel #304
  • Different plugs optional
  • Overheat, overvoltage protection
  • Air cooling or water cooling optional

Product Introduction:

Our Ozone Generator is CE-certified.

Product Description:

Our ozone generator applies PSA technology (pressure swing adsorption) and is a cost-efficient source of oxygen

This PSA oxygen generator is within the ozone unit.

The PSA Oxygen Generators/Concentrators work the same as the Nitrogen PSA Generators/Concentrators, with one exception: The absorption media inside is Zeolite.

Ozone is one of the most potent oxidation methods for water treatment professionals to purify and disinfect water.

Ozone is one of the most essential technologies used in both water and wastewater treatment. It is an effective process to decompose contaminants and produce cleaner water allowing you to cut back on expensive, corrosive chemical cost.

Ozone is created by applying an electrical charge to our PSA-produced oxygen molecules. The resulting ozone is then introduced into water for treatment and disinfection.

Characteristics:

Comes in 50 or 60 Hz models.

  • Our product stands out with its unique PSA technology featuring an imported oxygen molecular sieve
  • The 304 stainless steel housing is atmospheric, sleek, and built to last, ensuring the product's durability.
  • Our product boasts high conversion efficiency and low energy consumption, providing a long service life and cost-effectiveness.
  • Plug and play
  • Efficient and highly efficient in purifying and disinfection of water and wastewater.
  • Environmentally accepted generators, simply as ozone is produced, naturally become oxygen with no chance of residue being left behind.
  • Initial cost may be higher; however, ROI is favourable.
  • Can be used in many different applications.
Model Unit Pur-10G Pur-20G Pur-30G Pur-40G Pur-50G Pur-60G Pur-80G Pur-100G
O3 Output G/hr 10 20 30 40 50 60 80 100
Power Watts 510 700 770 800 890 900 1700 1900
O2 Flow rate LPM GPM 2-3 .44-.66 4-5 .88-1.10 6-7 1.32-1.54 8-9 1.76-1.98 10-11 2.2-2.42 12-13 2.64-2.9 16-17 3.52-3.74 18-20 3.96-4.4
Unit Weight Kg LBS 32.8kg 72.3lbs 42.4kg 93.5lbs 44.2kg 97.4lbs 48.3kg 106.5lbs 52.1kg 114.9lbs 55kg 121.3lbs 69kg 152lbs 72kg 158.7lbs
Dimension Cm Inches 50*40*73 19.7*15.7*28.7” 50*40*88 19.7*15.7*34.6” 50*40*108 19.7*15.7*42.5” 50*40*108 19.7*15.7*42.5” 50*40*115 19.7*15.7*45.3” 50*40*115 19.7*15.7*45.3” 50*40*163 19.7*15.7* 64.2” 50*40*163 19.7*15.7*64.2”
Voltage V/Hz AC
220-240
50-60
Concentration Mg/L 60-120
External case Stainless Steel 304
Working condition Up to
85%
humidity
10-37
degrees

WATER TREATMENT

REVERSE OSMOSISPUER WATER TREATMENT
INDUSTRIAL SEWAGE WATER TREATMENT
Hospital Waste Water Treatment
Swimming Pool Treatment
Aquaculture Water Treatment
Agriculture Planting
Fruit Vegetable Cleaning
Seafood Preservation

Benefits for Drinking Water

Municipal water companies have long trusted ozone technology to treat large volumes of water. This trust is a testament to the unwavering effectiveness of ozone in purifying and conditioning water. This reduces the clean-in-place (CIP) required to disinfect the operation.

Ozone is particularly effective when used in conjunction with other water treatment processes. Using reverse osmosis, nanofiltration, or ultrafiltration, ultrasonic algae treatment, and standard practices like coagulation and disinfectants in water treatment is advised. With this configuration, a large percentage of naturally occurring organic materials such as lignin, humic and fulvic acids can be removed, reducing the amount of ozone necessary to disinfect the water. Another benefit is that ozone will not lead to harmful trihalomethanes (THMs) formed when chlorine is added to raw water containing humic materials.

Benefits for waste Water

Ozone can be produced on-site using our inner PSA oxygen generator unit. The electricity required to produce the ozone can be generated using renewable methods at little ongoing cost to the facility. Ozone is renewable; the raw material is oxygen from our inner PSA oxygen generator unit. This eliminates the need to store ozone and reduces your footprint.

  • Ozone dissolves into oxygen, so there is no potential for hazardous residual chemicals remaining in the wastewater effluent.
  • Ozone has a higher oxidation potential than chlorine.
  • Ozone is more effective at disinfecting both bacteria and viruses from wastewater.
  • Ozone is more effective than chlorine at removing coloration from the wastewater.
  • Ozone is less likely to form carcinogens during usage.
  • Ozone is effective at lowering the pH of the wastewater.
  • Ozone has a half-life in water of 20 minutes, compared to two to three hours for chlorine.

Benefits of Ozone in Swimming Pools

Quick Disinfection

The disinfection process with ozone is a breeze. It occurs at the filter system in mere seconds, and then it’s gone, leaving you with a clean pool!

Destroys Irritants

With ozone, you can instantly say goodbye to irritants like chloramines. No more odours, itchy skin, or sore eyes. Unlike Ozone/UV light combinations, instead of chlorine for better health and the environment, ozone leaves no toxic or harmful residues. It’s a sure way to prevent eye irritations and clear your pool water.

Enriched Water

Returns only pure, oxygen-enriched water to your pool.

More powerful

Ozone and UV light treatment are potent and versatile solutions that do not introduce additional chemicals to pool water. They are a staggering 200 times more powerful than Chlorine and swiftly react with contaminants 3000 times faster.

Works instantly

Destroys algae spores, contaminants, viruses, and bacteria instantly and can easily be added to any new or existing pool.

Renewable resources

By choosing ozone and UV light, you’re not just getting a powerful pool maintenance solution; you’re also making a sustainable choice. Ozone and UV light are nature’s renewable resources, oxidizing organic and inorganic matter without forming by-products such as chloramines, which are responsible for the chlorine smell.

Benefits of Ozone in Aquaculture

Renewable resources

By choosing ozone and UV light, you’re not just getting a powerful pool maintenance solution; you’re also making a sustainable choice. Ozone and UV light are nature’s renewable resources, oxidizing organic and inorganic matter without forming by-products such as chloramines, which are responsible for the chlorine smell.

Removal of fine and colloidal solids

Fine and colloidal solids consist of particles 1-30 microns (mm) and 0.001-1 mm, respectively. The small size of the particles enables the solids to remain in suspension and avoid most mechanical methods of separation. The accumulation of fine and colloidal solids can impair biofilter nitrification efficiencies and stress fish stocks.

Ozone plays a crucial role in aquaculture systems by effectively removing fine and colloidal solids. It achieves this by clumping these particles together (microflocculation) and facilitating their removal through foam fractionation, filtration, and sedimentation.

Removal of dissolved organic compounds

Dissolved organic compounds (DOCs), also known as refractory organics, can significantly impact our aquaculture systems. They give the water a characteristic tea-coloured stain and are non-biodegradable, accumulating according to feed input, water exchange rate, and solids. High levels of DOCs can stress our fish and reduce the biofilter’s nitrification efficiencies, a concern we must address.

  • Oxidation into products that are more readily nitrified in the biofilter;
  • Including precipitation, which enables the removal of waste particles by conventional filtration or sedimentation.
Removal of Nitrite

Nitrite can accumulate as production intensifies and organic loadings on the biofilter increase. Bacteria that process ammonia into nitrite (Nitrosomonas spp) operate more efficiently under high organic loadings than bacteria that process nitrite to nitrate (Nitrobacter), and nitrite levels rise accordingly.

It’s crucial to note that high nitrite levels can be extremely toxic to our fish. Data available for silver perch Bidyanus biryanis indicates that nitrite levels as low as 2.8 parts per million (ppm) can reduce the growth of fingerlings by 5%, a significant impact we need to prevent.

Ozone removes nitrite by:
  • Direct oxidation to nitrate;
  • Reducing organic loading, which improves biofiltration efficiency and nitrification.
Disinfection

The high stocking densities, associated fish stress, and increased nutrient loads found in RAS (recirculating aquaculture systems) create an ideal environment for fish pathogens. Standard quarantine procedures for any fish introduced are an essential step in reducing the risk of disease outbreaks in RAS. Facilities using surface waters, including RAS and flow-through hatchery systems, are also interested in reducing the pathogen load introduced via the source water. The disinfection of effluent waters before introduction to the environment is also crucial to prevent the translocation of exotic diseases.

Ozone can effectively inactivate various bacterial, viral, fungal and protozoan fish pathogens. The effectiveness of ozone treatment depends on ozone concentration, length of ozone exposure (contact time), pathogen loads and levels of organic matter. If high levels of organic matter are present, the demand created by oxidizing the organic matter can make it challenging to maintain enough residual ozone for effective disinfection.

How to measure Ozone in your RAS:

The direct ozone measurement in a water sample is generally achieved using colorimetric test kits and spectrophotometry. However, these methods can be too coarse to detect the low residual levels lethal to some fish species and are unsuitable for continuous in-flow monitoring.

A common way of providing some level of constant in-flow monitoring for ozone is using oxidation-reduction potential (ORP) probes. Rather than measure ozone directly, an ORP probe measures the total capacity of various oxidants in millivolts (mV) in a solution to oxidize an electrode. These oxidants, often called ‘total oxidants, ‘include ozone and other reactive species such as chlorine and hydrogen peroxide. Keeping ORP measurements within a specific range, the levels of total oxidants can be controlled, which gives indirect control over ozone. A safe ORP level of freshwater fish culture is generally considered 300 mV.

Many systems automate ozonation by linking ORP measurement and the ozone generator. The generator switches off once the required ORP is reached and cuts back when the ORP drops again. This adaptability of ORP measurement to factors such as pH, temperature, and species culture reassures the system’s effectiveness. However, due to the lack of direct ozone measurement and because ORP probes can take several minutes to register a charge in ORP, any use of ORP to measure and control ozone application is approximate. For this reason, ozone control using ORP measurements is recommended to allow for some error and to set limits conservatively. Other water quality parameters, particularly nitrite, should also be monitored closely with ORP and used to gauge the effect of ozonation.

The Risks

Ozone is an effective oxidizing agent for water treatment and reducing pathogen loads in RAS. However, using any chemical of this nature is accompanied by considerable risks. RAS viability may be threatened in several ways.

  • Ozone’s reduction of nitrite levels carries a risk. The biofilter receives less nitrite, and the population of bacteria responsible for processing nitrite to nitrate diminishes. If any ozonation disruption occurs, dangerous nitrite concentration spikes can subsequently develop.
  • High residual ozone concentrations risk cultured fish stocks, causing gross tissue damage and stock mortalities.
  • High residual ozone concentrations are a risk to bacterial films on the biofilter. Disruption of biofilter performance can cause significant fluctuations in ammonia and nitrite levels. This can have a lethal effect on fish stocks or, at the very least, reduce stock health and growth performance.

It is recommended that a de-ozonation unit be installed directly after ozone application in an RAS to prevent toxic residual levels. This should be done regardless of the location of the ozone application in the system. A simple do-ozonation unit consists of a contact chamber to increase water retention time, allowing ozone to degrade. Alternatively, an in-line activated carbon filter or biofilter can also function as a de-ozonation unit. Degassing of residual ozone also occurs in packed column aerators and trickle filters. Any residual ozone gas should be vented from the RAS building and destroyed before release. Ozone is extremely toxic, and human exposure constitutes a serious health hazard. Decrease in lung function, aggravation of asthma, throat irritation and cough, chest pain, shortness of breath, and inflammation of lung tissue are typical symptoms of ozone exposure. In prolonged or severe exposure cases, chronic respiratory illnesses such as emphysema, chronic bronchitis, and premature aging of the lungs may occur.

Exposure standards for residual ozone in various Australian and international occupational health and safety administrations range between 0.05 and 0.1 ppm for an 8-hour work period and a maximum single dosage of 0.3 ppm for less than 10 minutes. Workcover Australia has a maximum exposure standard for residual ozone of 0.1 ppm for 8 hours.

Therefore, it is important to repeat the requirements of a leak-free ozone reactor made of suitable ozone-resistant materials. Venting sheds or areas of an RAS where ozone is used is also highly recommended. Humans can detect low residual ozone levels as a sharp, pungent odour, but continued exposure can quickly dull the senses. For this reason, perceived odour should not be used as an indicator of ozone presence.

Best Water Solutions Provider Awards

Puroxi Pure Water Global Inc was shortlisted for the awards category, Water Solutions Provider of the Year! As highlighted, it was some good news. I can confirm you that you have been chosen as the 2023/24 winners. Congratulations Zak! The generic winner’s logo has been attached which you can utilize to promote the recognition and the official press release will be conducted in March (defined date to come